Find My Check Valve
DFT® Vacuum Breakers provide effective protection against collapse of pressure vessels, tanks and rolls. They prevent condensate "back-up" when equipment is shut down or inlet steam is reduced by modulating control valves. In piping systems, DFT® Vacuum Breakers are used to break siphons, prevent pipe collapse during transient pressure drops, and to provide addition of air on the downstream side of check valves to dampen water hammer.
Unit of Measure
Items |
![]() 8094 1" 303 SS BSSV6 Style Vacuum Breaker Threaded In-Line Check Valve |
![]() 8103 1" 303 SS BSSV Style Light Spring Vacuum Breaker Threaded In-Line Check Valve |
![]() 8033 1" 303 SS BSSV Style Vacuum Breaker Threaded In-Line Check Valve |
![]() 8034 1 1/2" 303 SS BSSV Style Vacuum Breaker Threaded In-Line Check Valve |
![]() 8095 1 1/2" 303 SS BSSV6 Style Vacuum Breaker Threaded In-Line Check Valve | |||||
Series | N/A Vacuum Breaker | |||||||||
Style | N/A BSSV6 | N/A BSSV | N/A BSSV | N/A BSSV | N/A BSSV6 | |||||
Size | N/A 1.00 inDN 25 | N/A 1.00 inDN 25 | N/A 1.00 inDN 25 | N/A 1.50 inDN 40 | N/A 1.50 inDN 40 | |||||
Nominal Size (MNPT) A | N/A 1.00 in | N/A 1.00 in | N/A 1.00 in | N/A 1.50 in | N/A 1.50 in | |||||
Unthreaded Inlet Bore B | N/A 0.56 in14 mm | N/A 0.56 in14 mm | N/A 0.56 in14 mm | N/A 0.88 in22 mm | N/A 0.88 in22 mm | |||||
Friction Loss (Feet of Pipe) | N/A 7 | N/A 7 | N/A 7 | N/A 6 | N/A 6 | |||||
Friction Loss (Meter of Pipe) | N/A 2.1 | N/A 2.1 | N/A 2.1 | N/A 1.8 | N/A 1.8 | |||||
Valve Cracking Pressure1 | N/A 0.6 psi16.7 in.water424 mm.water31.1 mmHg0.041 bar | N/A 0.24 psi6.6 in.water167 mm.water12.4 mmHg0.017 bar | N/A 0.6 psi16.7 in.water424 mm.water31.1 mmHg0.041 bar | N/A 0.44 psi12.1 in.water307 mm.water22.6 mmHg0.03 bar | N/A 0.44 psi12.1 in.water307 mm.water22.6 mmHg0.03 bar | |||||
Valve Cracking Pressure Tolerance | N/A ±10% | |||||||||
Approx. Net Weight Each | N/A 0.38 lb0.2 kg | N/A 0.38 lb0.2 kg | N/A 0.38 lb0.2 kg | N/A 0.88 lb0.4 kg | N/A 0.88 lb0.4 kg | |||||
Cold Working Pressure2 |
N/A 0 psig6000 psig0 barg414 barg | N/A 0 psig2500 psig0 barg172 barg | N/A 0 psig2500 psig0 barg172 barg | N/A 0 psig2000 psig0 barg138 barg | N/A 0 psig5500 psig0 barg379 barg | |||||
Seat | N/A 316 SS | N/A 303 SS | N/A 303 SS | N/A 303 SS | N/A 316 SS | |||||
Disc | N/A 316 SS | |||||||||
Guard | N/A CF8M | N/A 303 SS | N/A 303 SS | N/A CF8M | N/A CF8M | |||||
Spring | N/A 316 SS | |||||||||
Retaining Ring | N/A 316 SS | |||||||||
Available Soft Seat Materials3 | N/A Buna-N (-70 to 250°F) EPDM (-75 to 300°F) TFE®-Viton® (-40 to 400°F) Viton® (-40 to 400°F) Zelon® (37 to 470°F) | N/A Buna-N (-70 to 250°F) EPDM (-75 to 300°F) TFE®-Viton® (-40 to 400°F) Viton® (-40 to 400°F) Zelon® (37 to 470°F) | N/A Buna-N (-70 to 250°F) EPDM (-75 to 300°F) TFE®-Viton® (-40 to 400°F) Viton® (-40 to 400°F) Zelon® (37 to 400°F) | N/A Buna-N (-70 to 250°F) EPDM (-75 to 300°F) TFE®-Viton® (-40 to 400°F) Viton® (-40 to 400°F) Zelon® (37 to 470°F) | N/A Buna-N (-70 to 250°F) EPDM (-75 to 300°F) TFE®-Viton® (-40 to 400°F) Viton® (-40 to 400°F) Zelon® (37 to 470°F) | |||||
ENDS | N/A NPT | |||||||||
ANSI | N/A B1.20.1 | |||||||||
MSS | N/A SP-25 | |||||||||
ASTM4 | N/A 303 SS not acceptable for CRN | N/A | N/A | N/A | N/A 303 SS not acceptable for CRN | |||||
Cv | N/A 5.8 | N/A 5.8 | N/A 5.8 | N/A 13.2 | N/A 13.2 | |||||
Applications | N/A Antisiphon Applications Boiler Feed & Discharge Heat Exchangers Irrigation System Jacketed Pans Steam Coils Steam Mains Steam Systems Sterilizing Chambers Storage Ressels Tanks | |||||||||
|