Print Back
The DFT® Restrictor Check Valve (RCV) is a versatile, all-purpose, spring-assisted, in-line check valve for applications that require higher cracking pressures to open the check valve than those offered by other DFT® check valves. Cracking pressures are available from 2 to 40 psi. Like the Basic-Check® valve, the Restrictor Check provides reliable, low maintenance service for a wide range of fluids and gases at various pressure/temperature combinations. The valve consists of a guard cage, spring, valve disc, retaining ring and seat. It can be combined with pipe fittings such as couplings, drain elbows, etc. (not provided by DFT®) to form a complete check valve unit ideally suited for a broad range of applications. The RCV should not be considered a substitute for a Pressure Relief Valve.
Restrictor Threaded In-Line Check Valves
Restrictor Threaded In-Line Check Valves
Unit of Measure
1 2 

Prod. #

Size

Line Size Inlet (FNPT) A

Outside Thread (MNPT) B

Valve Cracking Pressure

Cold Working Pressure

ENDS

Inventory

Rfi_link

Inventory

List Price

5642 N/A 0.25 in N/A 0.25 in N/A 1.00 in N/A 10.9 psi N/A 0 psig2500 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5650C204 N/A 0.25 in N/A 0.25 in N/A 1.00 in N/A 20.4 psi N/A 0 psig2500 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5641 N/A 0.25 in N/A 0.25 in N/A 1.00 in N/A 8.1 psi N/A 0 psig2500 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5639 N/A 0.25 in N/A 0.25 in N/A 1.00 in N/A 3.3 psi N/A 0 psig2500 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5640 N/A 0.25 in N/A 0.25 in N/A 1.00 in N/A 5.3 psi N/A 0 psig2500 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5646 N/A 0.375 in N/A 0.375 in N/A 1.00 in N/A 10.9 psi N/A 0 psig2500 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5651C204 N/A 0.375 in N/A 0.375 in N/A 1.00 in N/A 20.4 psi N/A 0 psig2500 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5645 N/A 0.375 in N/A 0.375 in N/A 1.00 in N/A 8.1 psi N/A 0 psig2500 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5643 N/A 0.375 in N/A 0.375 in N/A 1.00 in N/A 3.3 psi N/A 0 psig2500 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5644 N/A 0.375 in N/A 0.375 in N/A 1.00 in N/A 5.3 psi N/A 0 psig2500 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5619 N/A 0.50 in N/A 0.50 in N/A 1.00 in N/A 10.9 psi N/A 0 psig2500 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5652C204 N/A 0.50 in N/A 0.50 in N/A 1.00 in N/A 20.4 psi N/A 0 psig2500 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5618 N/A 0.50 in N/A 0.50 in N/A 1.00 in N/A 8.1 psi N/A 0 psig2500 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5616 N/A 0.50 in N/A 0.50 in N/A 1.00 in N/A 3.3 psi N/A 0 psig2500 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5617 N/A 0.50 in N/A 0.50 in N/A 1.00 in N/A 5.3 psi N/A 0 psig2500 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5637 N/A 0.75 in N/A 0.75 in N/A 1.50 in N/A 8.4 psi N/A 0 psig2000 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5653C155 N/A 0.75 in N/A 0.75 in N/A 1.50 in N/A 15.5 psi N/A 0 psig2000 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5635 N/A 0.75 in N/A 0.75 in N/A 1.50 in N/A 3.3 psi N/A 0 psig2000 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5636 N/A 0.75 in N/A 0.75 in N/A 1.50 in N/A 5.3 psi N/A 0 psig2000 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5654C155 N/A 1.00 in N/A 1.00 in N/A 2.00 in N/A 15.5 psi N/A 0 psig1500 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5654C318 N/A 1.00 in N/A 1.00 in N/A 2.00 in N/A 31.8 psi N/A 0 psig1500 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5654C407 N/A 1.00 in N/A 1.00 in N/A 2.00 in N/A 40.7 psi N/A 0 psig1500 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5623 N/A 1.00 in N/A 1.00 in N/A 2.00 in N/A 12.9 psi N/A 0 psig1500 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5620 N/A 1.00 in N/A 1.00 in N/A 2.00 in N/A 4.2 psi N/A 0 psig1500 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
5621 N/A 1.00 in N/A 1.00 in N/A 2.00 in N/A 6.1 psi N/A 0 psig1500 psig N/A NPT N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
Unit of Measure