Find My Check Valve
The SCV-R® is an in-line spring-assisted check valve designed for applications requiring "higher cracking pressures" than the DFT Model SCV® check valve. The SCV-R® is a self-contained check valve that installs directly in a pipeline and contains all of the proven features of the SCV® check valve.
51 - 75 of 103 | Results Per Page | View | Unit of Measure
1 2 3 4 5 
Clear Filter

Size (in)

Size (mm)

ENDS

ASME CWP

Cv

Prod. #

Size

Cold Working Pressure

Cracking Pressure CP

Body

ENDS

Cv

Inventory

Rfi_link

Inventory

List Price

845E7B4A5C029 N/A 1.00 inDN 25 N/A 0 to 750 psig0 to 51.7 barg N/A 0.2 bar2.9 psig N/A A351 CF8M N/A NPT N/A 17 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845E7B4A5C036 N/A 1.00 inDN 25 N/A 0 to 750 psig0 to 51.7 barg N/A 0.248 bar3.6 psig N/A A351 CF8M N/A NPT N/A 17 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845F7B4A5C135 N/A 1.25 inDN 32 N/A 0 to 750 psig0 to 51.7 barg N/A 0.931 bar13.5 psig N/A A351 CF8M N/A NPT N/A 32 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845F7B4A5C124 N/A 1.25 inDN 32 N/A 0 to 750 psig0 to 51.7 barg N/A 0.855 bar12.4 psig N/A A351 CF8M N/A NPT N/A 32 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845F7B4A5C159 N/A 1.25 inDN 32 N/A 0 to 750 psig0 to 51.7 barg N/A 1.096 bar15.9 psig N/A A351 CF8M N/A NPT N/A 32 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845F7B4A5C147 N/A 1.25 inDN 32 N/A 0 to 750 psig0 to 51.7 barg N/A 1.014 bar14.7 psig N/A A351 CF8M N/A NPT N/A 32 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845F7B4A5C088 N/A 1.25 inDN 32 N/A 0 to 750 psig0 to 51.7 barg N/A 0.607 bar8.8 psig N/A A351 CF8M N/A NPT N/A 32 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845F7B4A5C077 N/A 1.25 inDN 32 N/A 0 to 750 psig0 to 51.7 barg N/A 0.531 bar7.7 psig N/A A351 CF8M N/A NPT N/A 32 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845F7B4A5C112 N/A 1.25 inDN 32 N/A 0 to 750 psig0 to 51.7 barg N/A 0.772 bar11.2 psig N/A A351 CF8M N/A NPT N/A 32 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845F7B4A5C100 N/A 1.25 inDN 32 N/A 0 to 750 psig0 to 51.7 barg N/A 0.69 bar10 psig N/A A351 CF8M N/A NPT N/A 32 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845G7B4A5C139 N/A 1.50 inDN 40 N/A 0 to 750 psig0 to 51.7 barg N/A 0.958 bar13.9 psig N/A A351 CF8M N/A NPT N/A 36 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845G7B4A5C146 N/A 1.50 inDN 40 N/A 0 to 750 psig0 to 51.7 barg N/A 1.007 bar14.6 psig N/A A351 CF8M N/A NPT N/A 36 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845G7B4A5C151 N/A 1.50 inDN 40 N/A 0 to 750 psig0 to 51.7 barg N/A 1.041 bar15.1 psig N/A A351 CF8M N/A NPT N/A 36 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845G7B4A5C100 N/A 1.50 inDN 40 N/A 0 to 750 psig0 to 51.7 barg N/A 0.69 bar10 psig N/A A351 CF8M N/A NPT N/A 36 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845G7B4A5C125 N/A 1.50 inDN 40 N/A 0 to 750 psig0 to 51.7 barg N/A 0.862 bar12.5 psig N/A A351 CF8M N/A NPT N/A 36 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845G7B4A5C132 N/A 1.50 inDN 40 N/A 0 to 750 psig0 to 51.7 barg N/A 0.91 bar13.2 psig N/A A351 CF8M N/A NPT N/A 36 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845G7B4A5C181 N/A 1.50 inDN 40 N/A 0 to 750 psig0 to 51.7 barg N/A 1.248 bar18.1 psig N/A A351 CF8M N/A NPT N/A 36 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845G7B4A5C188 N/A 1.50 inDN 40 N/A 0 to 750 psig0 to 51.7 barg N/A 1.296 bar18.8 psig N/A A351 CF8M N/A NPT N/A 36 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845G7B4A5C197 N/A 1.50 inDN 40 N/A 0 to 750 psig0 to 51.7 barg N/A 1.358 bar19.7 psig N/A A351 CF8M N/A NPT N/A 36 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845G7B4A5C160 N/A 1.50 inDN 40 N/A 0 to 750 psig0 to 51.7 barg N/A 1.103 bar16 psig N/A A351 CF8M N/A NPT N/A 36 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845G7B4A5C167 N/A 1.50 inDN 40 N/A 0 to 750 psig0 to 51.7 barg N/A 1.151 bar16.7 psig N/A A351 CF8M N/A NPT N/A 36 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845G7B4A5C174 N/A 1.50 inDN 40 N/A 0 to 750 psig0 to 51.7 barg N/A 1.2 bar17.4 psig N/A A351 CF8M N/A NPT N/A 36 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845G7B4A5C086 N/A 1.50 inDN 40 N/A 0 to 750 psig0 to 51.7 barg N/A 0.593 bar8.6 psig N/A A351 CF8M N/A NPT N/A 36 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845G7B4A5C036 N/A 1.50 inDN 40 N/A 0 to 750 psig0 to 51.7 barg N/A 0.248 bar3.6 psig N/A A351 CF8M N/A NPT N/A 36 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
845G7B4A5C042 N/A 1.50 inDN 40 N/A 0 to 750 psig0 to 51.7 barg N/A 0.29 bar4.2 psig N/A A351 CF8M N/A NPT N/A 36 N/A
{0}
N/A =CASE WHEN {Inventory}=0 THEN {Rfi_link} ELSE CONVERT(VARCHAR(255),{Inventory}) END= {QUOTE}
51 - 75 of 103 | Results Per Page | View | Unit of Measure
1 2 3 4 5